RS-485 Bus Surge Protection Mounted on DIN Rail

SUG-RS485/DIN, RS-485 communication bus surge protection, protecting against the effects of atmospheric discharges, surges and potential difference jumps

The SUG-RS485/DIN is designed to protect the RS-485 bus from surges caused by atmospheric discharges and potential differences.

Modern solutions in the form of MOSFET fuses limit the flow of large surge currents through the limiter, resulting in increased durability and significant reduction of the surge voltage reaching the protected device. An additional advantage of this solution is the limitation of equalizing currents, which can protect RS-485 interfaces from potential jumps that lead to overcurrent.

The structure consists of voltage clipping and limiting stages, as well as a current limiter above 300mA. The product has very low attenuation, making it possible to transmit data at very high speeds.

The built-in additional protective circuit for the wire screen can be indirectly grounded through a gas discharge tube (GDT) or directly to the ground. Connecting terminals 3 and 4 closes the connection of the wire screen to the ground.

The overvoltage protection is designed to be mounted on a DIN 35mm rail. High-quality window clamps with high current load limit the risk of damage during large shock impulses and temporary current overloads. The device occupies the width of one DIN standard module.

The product is recommended for installation at the boundary of LPZ0 and LPZ1 zones or higher.

 

RS-485 Surge Protector

Simplified internal diagram.

 

To ensure proper overvoltage protection, it is recommended to use protective products at both ends of the transmission line and to properly ground them.

 

RS-485 Overvoltage Protection

Proper use of the product for protecting the RS-485 bus from overvoltage.

 

Short technical specification

PARAMETER NAME
VALUE
Number of protected tracks
3
Input / output connector Screw
Rated DC voltage (Un)
10V
Maximum DC voltage (Uc)
12V
Maximum AC voltage (Uc) 8V
Rated current (In)
300mA
C1: Line-to-line discharge current 8/20µs (In)
0.5kA
C2: Line-to-ground discharge current 8/20µs (In) 10kA
C2: Maximum line-to-ground discharge current 8/20µs (Imax) 20kA
D1: Maximum lightning current 10/350µs (Iimp)
3.5kA
Protection level 1kV/μs (line-line) Up 15V DC
Series resistance
7Ω / line
Dimensions 17.5 x 90 x 57 (mm)
Mounting method TH rail (DIN) 35mm
Grounding method Cable
Rail occupancy
1 module
Housing tightness IP20
Operating temperature -40ºC~80ºC