Surge arrester of 4 alarm detectors mounted outdoor, APS-4Zo/4P

  • Add feedback:
  • Code: APS-4Zo/4P
  • Manufacturer's code: 5904041751288
  • Weight: 0.1 kg
  • Availability: Duża ilość produktów Produkt available
    (shipping withing 24-48h)

Surge arrester for burglary alarm system, designed for 4 detectors mounted outside, built-it power separator, APS-4Zo/4P

The surge arrester is designed to protect burglary alarm panels against surges and lightning discharges. It has 4 protective channels for alarm detector signals and 4 independent power protection channels with separation. It is designed for use with detectors installed outside the building, where high-value spark jumps from metal structures, gutters or wires may appear. In addition to the danger to the alarm paths themselves, there is also a risk of damage to the control panel and connected devices as a result of a strong voltage increase in the power cables. This risk is eliminated by separating feeder protection by super-fast, automatically reset MOSFETs.

The product is made in the form of a module, mounted in a dedicated metal housing together with other modules that can create a comprehensive protection system for all control panel signals. The components used eliminate 10kA surge charges for each alarm and power supply circuit, using super fast MOSFET fuses, which prevents voltage impulses above 18V from getting on the protected side. This creates an effective protective barrier for any type of alarm system, without affecting even 4-state alarm circuits. The standard of the endangered and protected side terminals has been maintained in accordance with the standard of connection in alarm control panels, which ensures ease of installation and subsequent servicing.

The product cannot be used for addressable detectors, for this purpose a different model of protective device should be used.

The APS-4Zo/4P also has MOSFET fuses, separating the power supply of each alarm detector. This protects against neutralization of a group of detectors by shorting one of them. The fuses used have a very low current hysteresis and a response time of 1µs, which does not cause significant current consumption from the control panel even for a long period of short circuit. This solution also i preffered for Grade 4 alarm installations.

 

Surge arrester for burglary alarm system

Example of alarm zone protection for external detectors

 

Specification:

PARAMETER NAME
VALUE
Alarm zones
Protection channels (zones)
4
Input / Output connection Screw terminal
Rated Voltage DC (line-ground) UN 90V DC
Maximum Voltage (line-ground) UC 110V DC
Protection level 1kV/μs (line-ground) UP 600V
Surge current (8/20µs, line-ground) Iimp 10kA
Rated Voltage DC (line-line) UN 15V DC
Maximum Voltage (line-line) UC 13V DC
Protection level 1kV/μs (line-line) UP 18V (with MOSFET reaction)
Surge current (8/20µs, line-line) Iimp 2kA (with MOSFET reaction)
Decoupling element MOSFET fuse
Serial resistance 6Ω / line
Rated current IN 100mA / line
Power line
Protection channels 4
Rated Voltage DC (line-line) UN 13.8V DC
Maximum Voltage (line-line) UC 15V DC
Protection level 1kV/μs (line-line) UP 20V (with MOSFET reaction)
Surge current (8/20µs, line-line) Iimp 2kA (with MOSFET reaction)
Rated Voltage DC (line-ground) UN 90V DC
Maximum Voltage (line-ground) UC 110V DC
Protection level 1kV/μs (line-ground) UP 600V
Surge current (8/20µs, line-ground) Iimp 10kA
Rated current In 100mA / line
Common features
Dimensions 102 x 41 x 15 (mm)
Application Indoor
Mounting Designed housing
Operating temperature -30ºC~60ºC