Pelco-D protocol converter to Bosch biphase, CONV2-E

PelcoD PTZ protocol converter to biphase code, designed to control Bosch Speed Dome cameras, CONV2-E

    Product not available. Has been replaced by model CONV Pelco-Biphase
 
Protocol converter CONV2-E has been designed do control Bosch Security Speed Dome cameras by other PTZ keyboards, matrix switchers, or DVR's.
Protocol converter does receive PelcoD commands by RS485 and after translation send as Bosch biphase code.

Because Bosch cameras use a lot advanced commands, some of them are called by typical PelcoD commands: SET PRESET AND CALL PRESET.

The RS485 input have possibility to adjust baut rate and does support a lot cameras simultaneusly with address range 1~255.

Below was placed command list:

PelcoD command description- Bosch command description (Bosch command equivalent)

Learn pattern - Learn pattern A (ON 100 Enter)
Stop learn pattern - Stop learn patern A (OFF 100 Enter)
Run pattern - Run pattern A - constant (ON 50 Enter)
Auto-Pan start - ON 1 Enter
Left limit set - SET 101 Enter
Right limit set - SET 102 Enter
Start limit scan - ON 2 Enter
Set preset other - SET 100 ENTER
Call preset 127 - Lock advanced commands (ON-90 ENTER)
Call preset 95 - Entry to Main Menu (ON 46 ENTER)*
Call preset 126 - Display fast address (ON 997 ENTER)*
Call preset 124 - Go to home position (SET 110 ENTER)
Call preset 123 - On OSD screen (ON 60 ENTER)*
Call preset 100 - Run Tur (ON 8 ENTER)
Call preset 101 - Run Auto Tracking (ON 78 ENTER)
Call preset 102 - Run Pattern B (ON 52 Enter)
Call preset 103 - Clear Alarm (OFF 65 ENTER)
Call preset 115 - Stop learn pattern B (OFF 101 ENTER)
Set preset 127 - Unlock advanced commands (OFF 90 ENTER)
Set preset 125 - Edit Zone name (ON 63 ENTER )*
Set preset 123 - Off OSD screen (OFF 60 ENTER)*
Set preset 122 - Edit scan/auto-pan speed (ON 14 ENTER)
Set preset 121 - Edit tour time (ON 15 ENTER)*
Set preset 120 - Entry to password menu (SET 802 ENTER)*
Set preset 119 - Edit park function (ON 9 ENTER)*
Set preset 118 - Edit tour (SET 900 ENTER)
Set preset Other - Advanced scene edit (SET 100 ENTER)
set preset 116 - Edit scene name (ON 62 ENTER)
set preset 115 - Start learn pattern B (ON 101 ENTER)

* These commands are available after use
"Unlock advanced commands" (OFF 90 ENTER) - please refer to Bosch camera manual.