Patch panel with surge protection for Gigabit Ethernet, 16 channels

  • Add feedback:
  • Code: PTU-616R-ECO/PoE
  • Manufacturer's code: 5904041750618
  • Weight: 1.4 kg
  • Availability: Duża ilość produktów Produkt available
    (shipping withing 24-48h)

16-port patch-panel with surge protection system for gigabit LAN, compatible with Gigabit Ethernet 1000Base-T, PTU-616R-ECO/PoE

16-ports patch panel for Gigabit Ethernet networks witch surge protection system, built based on 5, 5e and 6th category cabling. It is composed of four PTU-64-ECO modules mounted in the PTU/PTF-6-RACK panel. It is designed for mounting in a 19 "Rack cabinet on the front rail. In IP-CCTV installations it can be mounted on the rear rail using LK-MOUNT angle brackets - many NVR's recorders have a built-in LAN switch and all connectors on the back.

The RJ-45 connectors on the front (DEVICE) are protected against surges. The Gigabit Ethernet LAN ports are connected to them using patch cords. The rear LSA connectors are an unprotected side (LINE), where long LAN cables are connected without the use of RJ-45 connectors. This design creates two devices in one: LAN patch panel with RJ-45 sockets and effective surge protection. This solution simplifies the installation, reduces the number of additional elements and reduces costs. To ensure continuity of FTP cable shield, shielded patch cords and metal clamps on PCBs should be used.

The PTU-64 series modules are high-quality surge protection products with low signal losses. The use of multilayer PCBs and modern components resulted in compliance with the correct tests for 4x125MHz frequency.

Independent PoE protection circuits eliminate the overvoltages between 1.2 - 3.6 and 4.5 - 7.8 pairs in the LAN cable. This solution protects power supplies of LAN equipment against damage due to lightning surges or uncontrolled voltage increase, for example as a result of damage to the PoE power supply. The solutions used are compatible with each PoE standard, including Hi PoE.

Ensure proper grounding of the surge arrester by connecting the supplied grounding cable to PE line. The optional PTU/PTF-COVER protects PCB from dust, it also provides an additional shield against interference.

The best level of surge protection is obtained by installing surge arresters on two sides of the LAN cable. Multi-channel surge arrester at the LAN switch side and one-channel surge arrester at the LAN device side - for example PTF-61-ECO/PoE or better model.

The product is designed for LAN installations LAN with all cables and devices placed inside of buildings. For installations in part installed outside or greater risk of damage we suggest use model PTF-616R-EXT/PoE.

 

Patch panel LAN with surge protection

Complete surge protection with the PTU-616 used as patch panel

 

Specification:

PARAMETER NAME
VALUE
Data line
Number of LAN channels 16
Supported Ethernet standards
10Base-T, 100Base-T, 1000Base-T
Compatibility with cabling Category 5, 5e i 6 (TIA)
Input connector (unprotected side) LSA connector
Output connector (protected side) RJ-45 socket certified for 6 category
Rated Voltage DC (line-ground) UN 90V DC
Maximum Voltage (line-ground) UC 110V DC
Protection Level 1kV/μs (line-ground) UP 600V
Surge Current (8/20µS, line-ground ) Iimp 100A
Rated Voltage DC (line-line) UN 3.3V DC
Maximum Voltage (line-line) UC 3.5V DC
Protection Level 1kV/μs (line-line) UP
28V
Surge Current (8/20µS, line-line) Iimp 100A
Protected lines
1-2, 3-6, 4-5, 7-8
Capacitnance (line-line) @1MHz 15pF
Capacitnance (line-ground) @1MHz 2-3pF
Serial resistance
2.2Ω / line
Rated Current IN 300mA / line
PoE Line
Rated Voltage DC (line-line) UN 57V DC
Maximum Voltage (line-line) UC 64V DC
Protection Level 1kV/μs (line-line) UP 90V
Surge Current (8/20µS, line-line) Iimp 100A
Rated Voltage DC (line-ground) UN 90V DC
Maximum Voltage (line-ground) UC 110V DC
Protection Level 1kV/μs (line-ground) UP 600V
Surge Current (8/20µS, line-ground ) Iimp 100A
Protected pairs
(1+2)-(3+6), (4+5)-(7+8)
Supported PoE standards
Compatible with all types including Hi PoE
Common features
Dimensions 480 x 41 x 130 (mm)
Application Indoors
Mounting 19" Rack cabinet
Grounding method Earthing conductor
Operating temperature -30ºC~60ºC